Current Control Mode
Current Control Mode
|
Type: |
|
|
RMC70 Address: |
Fn:6, where n = 8 + the axis number |
|
RMC150 Address: |
Fn:6, where n = 8 + the axis number |
|
System Tag: |
_Axis[n].CtlMode, where n is the axis number |
|
How to Find: |
Axes Status Registers Pane, All tab: Control |
|
Data Type: |
|
|
Units: |
– |
Description
The Current Control Mode is the control mode that the axis is currently in. The Current Control Mode register does not indicate whether the axis is in pressure or force limit. Use the Status Bits register for pressure or force limit information.
|
Values |
Control Mode |
|
0 |
None |
|
1 |
Direct Output |
|
2 |
|
|
3 |
|
|
4 |
|
|
5 |
|
|
6 |
Any motion command that switches the control mode will affect this register. For example, issuing Direct Output (9) or Open Loop Rate (10) commands will change this register to values of Direct Output (1) and Open Loop (2). Also, issuing closed loop motion commands will switch the control mode to the control mode specified by the Next Pos/Vel Control Mode register. Use the Set Pos/Vel Ctrl Mode (68) command to change the value of this register, and thus control which closed loop control mode will be used.
See Also
Status Registers | Next Pos/Vel Control Mode | Default Pos/Vel Control Mode | Set Pos/Vel Ctrl Mode (68)
Copyright (c) 2005-2012 by Delta Computer Systems, Inc.